Back to top
08045802318
Send SMS Send Inquiry


      High Voltage Tester Transformer

      High Voltage Tester Transformer

      50000 INR/Unit

      Product Details:

      • Low Voltage 110 Volt (V)
      • High Voltage 440 Volt (V)
      • Material Mild Steel
      • Usage For Electric Transformer Use
      • Weight 20-50 Kilograms (kg)
      • Click to View more
      X

      High Voltage Tester Transformer Price And Quantity

      • 50000 INR/Unit
      • 1 Unit

      High Voltage Tester Transformer Product Specifications

      • For Electric Transformer Use
      • Mild Steel
      • 20-50 Kilograms (kg)
      • 110 Volt (V)
      • 440 Volt (V)

      High Voltage Tester Transformer Trade Information

      • Cash on Delivery (COD) Cheque
      • 1 Unit Per Day
      • 1 Week
      • Western Europe Australia Eastern Europe Central America Middle East South America Asia North America Africa
      • All India

      Product Description

      Technical Specification

      Open circuit voltage

      0 to 5KVORo to 10 KVAC. The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.

      Test Current

      2mA to 20 MA or 3mA to100 MA

      Accuracy reading power

      +/-2%

      Requirement Safety

      230 volts AC, +/- 10%, 50/60 Hz

      Transmission

      Protection provided with zero start to prevent accident availability of High Voltage

      Precautions

      Voltage on test terminals. High Voltage on test jig appears only after the variac is set to zero and gradually increased. There is a trip device to trip if the current increases than the required value

      Trip Setting

      The tripping can be set by a pot which can be varied as peruser requirement


      Specifications for 0 to 50/75/100 KV H.V Tester

      Open Circuit voltage

      0 to 30/ 50/75/100 KV AC.

       

      The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.

      Test Current

      5 mA to 50 mA or10 mA to 300 mA

      Accuracy reading power

      +/-2%

      Power Requirement

      230 volts AC, +/- 10%, 50/60 Hz

      Safety Precautions

      Protection provided with zero start to prevent accident availability of High Voltage on test terminals. High Voltage on test jig appears only after the variac is set to zero and gradually increased. There is a trip device to trip if the current increases than the required value

      Trip Setting

      The tripping can be set by a pot which can be varied as per user requirement

      Tell us about your requirement
      product

      Price:

      Quantity
      Select Unit

      • 50
      • 100
      • 200
      • 250
      • 500
      • 1000+
      Additional detail
      Mobile number

      Email

      Other Products in 'Industrial Transformer' category